Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 30 days
Quality Assurance
The supplier provides quality assurance
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
  • Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
  • Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
  • Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
  • Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
  • Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
Find Similar Products

Basic Info.

Model NO.
LT-TS2-280F
Type
Test Chamber
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Other
Display
Digital
Control
Computer Control
Weight
500-1000Kg
Power Source
AC220V
Temperature Range
-45~200ºC
Transport Package
Wooden Case
Specification
W3100*D1400*H1900 (mm)
Trademark
LITUO
Origin
China
HS Code
8514109000
Production Capacity
10000/Year

Product Description

Suitable for electronic and electrical, instrumentation, home appliances and other products, parts and materials in the temperature change (cold and heat shock) environment storage, transportation, use adaptability test (reliability test)
Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment
Equipment characteristic

1. Pre-cooling temperature range in low temperature zone: -65ºC ~ 0ºC.
2. High temperature zone preheating temperature range: +60ºC ~ +200ºC.
3. High and low temperature conversion time: 5min.
4. Temperature fluctuation: ±0.5ºC.
5. Temperature uniformity: ≤±2.0ºC.
6. Test holding time: >=15min (adjustable).
7. Energy storage area rising and cooling rate:
    Average cooling rate in low temperature zone: (0.7 ~ 1.5) ºC/min.
    Average heating rate in high temperature zone: (3.0 ~ 6.0) ºC/min.
8. Test weight: 15 KG (other specifications can be customized).
9. System noise: 68 DB.
10. Power supply: AC3 5W 380V±10%; 50HZ.
11. Use air source (compressed air) : pressure: (5 ~ 7)kg/cm2
12. Power: 18.5KW.
13. Maximum working current: 35.0A.
14. Weight: 900KG
15. The rate of temperature change is the average rate of air temperature change, rather than the rate of surface or internal temperature change of the product.
16. The performance measured after 20 minutes of stability without test load and without shelf.
17. The temperature sensor is set in the circulation motor outlet.
18. Temperature uniformity is defined as the data measured at the geometric center point of the experimental machine (measurement unit space 9-point temperature measurement method).
19. Equipment fault protection: overheat protection circuit breaker, leakage protection, compressor overload protection, control system overload protection, phase sequence
Protection, water shortage protection, high pressure and low pressure protection, over temperature protection, fan overcurrent protection.


Structure of equipment
1. Basket size: W2000*D700*H200 (mm).
2. External dimensions (approx.) : W3100*D1400*H1900 (mm).
3. Case material: a. Outer box material: Baosteel high-quality steel plate electrostatic spray treatment; b. Inner box material: SUS304# heat-resistant and cold-resistant stainless steel plate.
4. Insulation material: polyurethane foam + high temperature rock wool board insulation.
5. Outer box base: national standard Angle iron + national standard channel steel + special anti-rust treatment of electrolytic plate spray.
6. Test box door (double door) :
 a. Material: same as the test box.
 b. Handle: stainless steel handle.
 c. Rear button :SUS#304.
 d. Test hole: there is 1 hole with a diameter of 50mm on the left side of the body, 1 stainless steel hole cover, and 1 silicone plug head.
7. Forced air circulation system: a. long shaft motor: AC220V 120KW extended shaft motor ×2 sets; b. Multi-wing wind turbine.
8. Heating system: Moisture-proof and low-temperature SUS316L stainless steel heating wire durable.
9. The equipment is equipped with air pressure balance and explosion-proof configuration, and the air pressure balance port balances the air pressure inside and outside the work room.


Heat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab EquipmentHeat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab EquipmentHeat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab EquipmentHeat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab EquipmentHeat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab EquipmentHeat and Cold Testing Instruments Hot and Cold Impact Test Chamber Lab Equipment

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier