Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1. Inner box size (W*H*D) : Double layer, each layer W600*D600*H850 (mm) |
2. Outer box size (W*H*D) : W950*D1900*H2150(mm) |
3. Temperature range: -40ºC ~ +100ºC |
4. Temperature fluctuation: ≤±0.3ºC(constant state space-time load |
5. Temperature uniformity: ≤2.0ºC(constant state space-time load |
6. Temperature deviation: ≤±1.0ºC(constant state space-time load |
7. Rising and cooling rate: Cooling rate: +25ºC ~ -40ºC≤60min, average cooling rate: (0.7 ~ 1.0) ºC/min(the whole average no-load). Heating rate: +25ºC ~ +100ºC≤40min, average heating rate: 0.5 ~ 3.0ºC/min(the whole average no-load |
8. Common temperature conditions: 60 ºC, 45ºC, 25ºC, 0ºC, -10ºC, -20ºC, -40ºC; It is about 3 months long Phase low temperature test condition (-40ºC) |
9. Equipment layout: Circulating water inlet and outlet, spray water inlet and outlet are located on the left, pressure relief port is located on the right; Circulation water inlet and outlet, spray water inlet and outlet are located on the right, pressure relief port is located on the left; Note: From the position of the main door of the equipment; The device configuration ratio in the two layouts depends on the actual purchase requirements. |
10. Equipment volume: 306L (600×850×600 mm) per layer, a total of 2 layers |
11. Operation mode: Double-layer independent temperature control, can be set to run or program run. |
12.Equipment weight: ≤550kg |
13.Voltage: AC 380V±10%, 50 Hz, three-phase four-wire + ground wire |
14.Ambient temperature: 0 ~ 40ºC |
15.Ambient humidity: < 85%R.H (25ºC) |
16.Atmospheric pressure: air pressure 86 ~ 106Kpa |
17.Equipment power: 9kw |
18.Power distribution circuit breaker specifications: 63A/3P+N |
19.Equipment wire specifications: 3*6+2*4 (three-phase five-wire system |
20.Device cable inlet: One cable inlet at the top of the device |
21.System noise: ≤68dB (500mm from the surface of the equipment and operating bit, respectively) |
22.Cooling method: water-cooled (customers provide frozen water |
23.Inlet flow rate: ≤2m³/H |
24.Water inlet temperature: 5-32ºC |
25.Inlet pressure: 0.2MPa |
26.Environment heat dissipation: ≤0.3KW |
27.Equipment fault protection: overheat protection circuit breaker, humidification system overheat protection, compressor overload protection, control system overload protection Protection, overload indicator light, phase sequence protection, water shortage protection, high pressure and low pressure protection, over temperature protection, water supply delay protection, fan overcurrent protection. |